A Full Re-Roof and Structural Timber Renewal

When a homeowner got in touch with us on 4th August, they were looking for a full re-roof and some much-needed modernisation. What they didn’t anticipate was a serious structural issue hiding beneath the existing tiles. Fortunately, that’s exactly the sort of challenge our team is built for.

By 26th September (just seven weeks later), the property had a brand new roof, structurally reinforced gable ends, fresh fascia, soffits and guttering, and a very happy customer.

A Full Re-Roof and Structural Timber Renewal

A Full Re-Roof with More Than Meets the Eye

The original enquiry was straightforward enough: the homeowner wanted to replace their ageing roof with a modern, durable system using breathable felt, treated battens and interlocking concrete tiles. We also quoted to re-point the chimney, renew the leadwork and replace all fascia, soffits and guttering in white uPVC (excluding the existing downpipes).

As always, our proposal included everything needed for a professional and safe working environment, scaffold, site welfare, skips, waste removal and full site clean-up.

But it’s what lies beneath the existing coverings that would become the real test.

A Hidden Problem Revealed

Once the team began stripping back the old roof coverings and fascia boards, they uncovered something no one had anticipated: extensive timber decay across both gable ends. The existing gable frameworks were structurally compromised well beyond repair, posing a risk not only to the integrity of the new roof but to the building as a whole.

Situations like this can’t always be predicted at the quotation stage. Until the old roof comes off, underlying issues are often hidden from view but when they do emerge, they need to be addressed properly.

How We Handled It

We immediately halted progress and explained the issue to the homeowner. Transparency is key in situations like this. No work was carried out without full agreement on the scope, timeframe and additional cost for labour and materials.

Our solution was to dismantle the affected timber and renew the entire framework using treated structural-grade timber, reinstated in full compliance with current building standards. This safeguarded the long-term integrity of the roof and gave the client peace of mind that the problem had been dealt with thoroughly.

The Re-Roof: Built to British Standards

With the structural issue resolved, we moved on to the full re-roof, carried out to the same high standard as always.

Scope of Works Included:

  • Removal of all existing roof coverings, including tiles, battens, ridge tiles and underlay
  • Installation of Cromar Vent 3 Pro breathable felt membrane manufactured to meet the wind uplift and durability standards in BS 5534
  • Fixing of graded Lokarr Yellow Treated Roofing Battens, compliant with BS 5534:2014+A2:2018 for structural performance and durability
  • Supply and installation of Redland 49 concrete interlocking tiles in Tudor Brown for a clean, consistent finish
  • New ridge tiles to match the tile profile, installed using a ventilated dry ridge system and fixed in accordance with BS 8612

Chimney and Leadwork

We also repointed 7m² of the chimney using a suitable mortar mix to ensure structural stability and a weatherproof seal.

Leadwork included:

  • New lead soakers and flashings
  • New apron and back gutter
  • All lead fixed securely with hall clips and sealed with lead sealant
  • Installation to Lead Sheet Association standards with Code 5 300mm lead
  • Patination oil treatment for enhanced durability and a longer-lasting finish

Every element was installed using methods and materials aligned with current British Standards, ensuring compliance and longevity.

Fascia, Soffits and Guttering Replacement

Alongside the roof replacement, we stripped out the existing fascia, soffits and guttering (excluding the downpipes) and installed a full white uPVC system.

Specification:

  • White uPVC fascia boards, 18mm thick full-replacement type with square edge profile
  • White uPVC soffits, available in both solid and vented options to meet ventilation requirements under Building Regulations Part F
  • New uPVC guttering, compatible with BS EN 607 and BS EN 12200-1, aligned for correct falls, with watertight joints and a clean finish
  • All fixings were corrosion-resistant, with concealed joiners and trims for a polished, consistent appearance

We also took care to inspect the rafter feet and wall plate for any additional signs of decay before proceeding.

Waste Removal and Site Finish

As part of our environmental and safety commitments, all waste was cleared from site, with multiple skips used as needed. The scaffolding was dismantled promptly upon completion, and the work area was left clean, tidy and hazard-free.

Project Timeline: 4th August – 26th September

Despite the structural issue uncovered mid-way through, the entire project (from first contact to final clean-up) was completed in just under seven weeks.

Thanks to clear communication and rapid on-site decision making, the added works were integrated into the schedule with minimal disruption to the homeowner.

Why Material Choice Matters

We don’t cut corners on materials. Every product we use is selected for its performance, compliance and reliability.

  • Lokarr battens: Graded to BS 5534 for strength, durability and precise sizing
  • Cromar Vent 3 Pro: Breathable membrane designed to resist wind uplift, in line with BS 5534
  • Redland 49 tiles: Trusted, durable and ideal for UK conditions
  • Leadwork: Installed to Lead Sheet Association guidance using Code 5 lead for longevity

Choosing approved, certified materials means fewer problems later on, and a finish that holds up not just for a few years, but for decades.

A Delighted Customer

The client was thrilled with both the result and the experience throughout. Here’s what they had to say in their Trustpilot review:

“Amazing service from start to finish. Professional and good at what they do!”

It’s feedback like this that drives our team. We’re proud to offer not just roofing solutions, but reassurance, clarity and long-term value.

Need a Roofing Expert?

This project is a textbook example of how a seemingly routine re-roof can evolve into something far more complex and why it’s crucial to work with a team that’s equipped to handle the unexpected.

If you’re planning a roofing project or need advice on the condition of your roof, we’d be happy to help. From timber repairs to tile replacements, we do it properly.

Learn more about our re-roof services or call our team today on 01323 810 555.

Enjoyed it? Share it!

Read our other case studies .

Juniper Roofing Southern LTD Logo
We offer product Guarantees and workmanship guarantees on certain product and installation works for new roofs and re-roofs.
Juniper Roofing Southern - StrataPlan CertifiedDBS Verification Badge

Registered address: 31 Willingdon Road, Eastbourne, East Sussex BN21 1TN.       Company Registration Number: 15706433.

VAT Registration number: 502034161

Call us on: 01323 810 555

If you have need for immediate repair, we're ready to speak with you.
In the event that we cannot answer, please leave a voice message and we'll get back to you as soon as we can!

You can also send us a message

Get in Touch with Us

Have a question or want to learn more about what we do?
We're here to help you.

You can also call us: 01323 810 555